Coal Carbon and Hydrogen (C.H) Analyzer

Model: KR-CH46

C.H analyzer

The integrated fast automatic hydrogen measuring instrument complies with the national standard GB/T476-2008. It is mainly used to determine the content of hydrocarbon elements in coal and other solid materials. The test process adopts the integrated control of the single-chip microcomputer, and the test data is corrected and processed by the single-chip microcomputer. The number of milligrams or percentages of hydrogen in the measured substance is digitally displayed, and the final result is output by the printer. The instrument measures quickly, the results are accurate, the operation is simple, and the degree of automation is high. The number of milligrams of hydrogen in the measured substance is displayed digitally, and the dry basis content of hydrogen is automatically printed out.

The appearance design is novel, the operation is convenient, the use space is reduced, and the maintenance is more convenient. The instrument can also determine the carbon content in coal and other solid materials.

Technical indicators and parameters:

Measurement range: hydrogen 0-10%, carbon 1-100%
Heating speed: 50min can rise to 850℃
Measurement time: about 10-15min
Measurement accuracy: meet the requirements of 15460-2003
Instrument stability linearity: ±0.1%
Allowable error: hydrogen: ≤0.15% (same laboratory), carbon: ≤0.50%
Power supply: AC220V±10%, 50Hz
Power: 3Kw
Temperature control: 800℃±10℃, 300℃±10℃
Linearity: ±0.1%

Online Inquire

ASTM D525 Oxidation Stability of Gasoline Tester

Model: KR-OS800

astm d525 gasoline oxidation stability tester

 

This Oxidation Stability of gasoline analyzer is designed and manufactured according to the requirements of GB / T 8018-87 “Gasoline Oxidation Stability Test (Induction Period Method)”, and is suitable for testing the oxidation stability of gasoline under accelerated oxidation conditions according to GB / T 8018 standard. Also meets ASTM D525 standards.

 

Main feature:

 

1. LCD display, fast heating

2. Can do two sets of experiments at the same time

ASTM D525 Gasoline Analyzer/Oxidation Stability Lab Testing Equipment

 

Technical Parameters: 

 

Working power supply: AC220V±5%, 50Hz

Sensor: Pt100 (platinum resistance)

Bath hole: 2 holes

Heating tube power: 1800W

Oxygen bomb pressure transmitter measuring range: (0~1600) kPa, accuracy: ±2‰

Water bath temperature control point: 100.0 °C ± 0.1 °C

Thermometer: equipped with a glass mercury thermometer, you can adjust the system at any time as needed.

Ambient temperature: ≤30°C

Relative humidity: ≤85%

Online Inquire

ASTM D2699 D2700 MON and RON Analyzer for Diesel Gasoline

Model: KR-A

This diesel gasoline MON RON analyzer is in line with American Society for Testing Materials Standards: ASTM D 2700 (Motor Method) and ASTM D 2699 (Research Method). In line with the national “Determination of Gasoline Octane Number”: GB/T 503-2016 (Motor Method) and GB/T 5487-2015 (Research Method) Used for determining the octane number of vehicle gasoline and ignition aviation engine gasoline. The instrument host uses a CRF standard single-cylinder four-stroke motor with the continuous variable compression ratio, with an industrial control computer, a Windows operating system, high-precision measurement and control components and other many peripheral devices to accurately and effectively perform testing. The tester has many auxiliary functions such as auto display, saving and printing of test report.

 

RON Analyzer

Instrument Features

-CFR standard engine with the professionally mechanical processing.

-CFR standard integral cylinder; integral cooling jacket; inblock casted cylinder body and cylinder cover; they can be interchanged with the imported instrument components.

– CFR standard piston stroke is 114.3mm, with high resolution to guarantee stable high compression ratio test.

– CFR standard large linage mechanism, to ensure high compression ratio stroke to effectively ensure the service life of more than ten years of the mechanical parts.

– With the standard CFR crankcase design; five gears with dual balance module and high-capacity oil lubrication system; good thermal stability to guarantee a long-term smooth operation.

– With one machine for two purposes; the combined pulley is used to quickly switch over the Research. Method and the Motor Method

– A new sized mixing heater; switching between Research Method and Motor Method without dismantlement.

– With the accurate compression ratio method test; built-in work curve to get the test results conveniently and quickly.

– High-precision sensor and integrated control module to monitor the working conditions of the instrument in real time, with the abnormity alarm function.

– The operating software is based on WIN7 system; with the screen to display the knock meter and knock signal.

– Built-in atmosphere pressure automatic compensation module.

– With the compression ratio auto adjustment and limit safety protection.

– With a simple linkage mechanism and with an auto display of the ignition angle in real time.

– The vertical nozzle and fourth oil cup carburetor have refrigeration function to guarantee the light component oil test.

– The carburetor has four independent horizontal spray pipes and one-way vertical spray pipes to accurately control the air-fuel ratio.

– With the auto level search function, simply the maximum knock signal adjustment.

– With a high-power dual-cycle air constant-temperature dryer, to effective support the intake air amount required by the engine with a large cylinder bore

– A professional high-power cooling water circulation machine, with the water tank capacity ≥60L for environmental protection and test.

– A laser displacement sensor, without delay for adjustment; with the limit safety protection function.

– A high-precision knock sensor, with millisecond response.

– With two-stage oil filtering and cooling function, to effectively cool down oil and to ensure a long-time smooth operation.

– With an oil preheat function as the standard configuration, shortening the warmup time.

– With the stainless steel cooling water tower, to avoid corrosion to the internal circulation water channel and to improve the cylinder liner cooling effect.

– With the phase protection device and emergency stop button, to achieve emergency protection in case of emergency.

– Large-capacity data memory and remote failure diagnosis.

– With safety alarm and maintenance prompt – Cumulative time recording of startup and test.

 

Technical Parameters of octane and cetane tester:

– Octane number test range: 40~120

– CFR standard cast iron integral cooling jacket; inblock casted cylinder body and cylinder cover.

– Cast iron cylinder bore: 82.55mm (3.250in)

– Cast iron piston stroke: 114.3mm (4.5in)

– Cylinder capacity: 0.61L (37.33in3)

– CFR standard crankcase; five gears with dual balance module; right-mounted engine; front turning system – The main machinery components such as integral cylinder, holder, piston and carburetor parts are interchanged with the components of the imported instrument.

– Compression ratio adjustment range: 4:1~8:1

– Engine speed: Motor Method (900±8) r/min

Research Method (600±6) r/min

– Valve clearance: intake valve: 0.20mm;

exhaust valve: 0.20±0.025mm

– Spark plug clearance: 0.51±0.13mm

– Lubricant pressure: 172~207Kpa

– Lubricant temperature: 57±8℃

– Cylinder jacket coolant temperature: 100±1.5℃

– Mixed gas temperature (Motor Method): 149±1℃

– Intake temperature (Motor Method): 38±2.8℃

– Intake temperature (Research Method): 52±1℃ (under the standard atmospheric pressure), corrected with the atmospheric pressure

– Ignition advanced angle: Motor Method: ε5.0 (26±1.5℃); adjusted by the computer automatically Research Method: (13º), fixed

– High-power dual-cycle refrigeration ice tower with the temperature controlled 2 to 4℃, to effectively support air intake

– High-power cooling water circulator, with the water tank capacity ≥60L; water pressure: 0.2~0.4Mpa; Working water temperature: 15~25℃

– Power supply: AC380V±10%, 50Hz, AC200V±10%, 50Hz

– Machine power: 12kW Accessories power: 7kW

– Instrument size: 1700Wx900Dx1400H (mm)

– Machine weight: 1200kg

Online Inquire

ASTM D86 Oil Distillation Range Testing Equipment

Model: KR-ZL8

The petroleum products distillation range laboratory testing equipment is designed and manufactured according to the requirements specified in GB/T 255 “Petroleum Product Distillation Measurement Method” and SH/T 0121 “Technical Conditions for Petroleum Product Distillation Range Measuring Device” to determine the distillation composition of liquid fuel, solvent oil and light petroleum products.

fuel distillation tester

Main Features:

1. Adopting the integral lifting mechanism, the heating furnace is easy to rise and fall and running smoothly.

2. The water bath is made of stainless steel, which is corrosion resistant and durable.

3. The heating furnace adopts electronic voltage regulation technology to achieve continuous and stepless adjustment of heating power.
Main Specifications:

 

Main Specifications oil distillation test apparatus:

 

Distillation flask:

 

Made of hard glass and heat resistant to 500 °C or higher.

The diameter of the flask is Φ69mm±1mm, and the neck of the bottle is Φ16mm±1mm.

The branch pipe and bottle neck are 75 ° degrees±3 °.

Electric furnace gasket: Made of silicon carbide, the outer diameter isΦ105mm, and the inner diameter is Φ50mm, Φ30mm.

 

Thermometer: 0-360 °C, the index is 1 °C, which meets the requirements of GB/T 514.

 

Condensation tank: Made of stainless steel, the condenser is refined with a Φ16mm*1mm brass tube.
Heating adjustment: Consists of a fueling device, a controllable thermostat circuit and a control panel. The heating device power is 1000W, and the heating rate is continuously adjustable.
Working environment: Ambient temperature -10~+35 °C, relative humidity less than or equal to 85%.

 

Working power AC220V 10%, 50Hz.

 

Power consumption of the whole machine: no more than 1100w

 

ASTM D86 D850 Automatic Petroleum Distillation Range Apparatus

Model: KR-ZL808

This petroleum distillation range apparatus is an full automatic distillation test instrument used to determine the atmospheric distillation range of petroleum products. It is suitable for use in accordance with GB/T6536 “Determination of the atmospheric distillation characteristics of petroleum products” and GB/T7534 “Determination of the boiling range of industrial volatile organic liquids”, ASTM D86, ASTM D850, ASTM D1078 and other standards, for gasoline, aviation gasoline, jet fuel, special boiling point solvents, naphtha, diesel, distillate fuel, industrial volatile organic liquids and similar petroleum products for distillation determination.

automatic distillation equipment

Main technical features:

1. This distillation test machine adopts embedded computer, imported industrial computer, 10-inch large-screen LCD touch screen, friendly man-machine dialogue interface, and convenient test operation.

2. Using single-chip microcomputer and intelligent control technology, the heating and cooling of the distillation test process, distillate level tracking, distillation rate control, recovered liquid volume control, temperature recording, test result printing, etc., are all automatically completed.

3. The three curves of steam temperature, heater temperature and distillation rate can be displayed in real time during the whole process of the test, and it can be judged in real time whether the relevant indicators meet the requirements of the test standard.

4. Applicable standards and distillation procedures can be added according to user needs and test oil samples, and can be called at any time.

5. With the automatic detection function of atmospheric pressure, the atmospheric pressure correction is automatically completed, and the test results are not affected by atmospheric changes.

6. After the test, enter the residual amount to automatically calculate the evaporation temperature.

7. Fill the cold bath with antifreeze, built-in circulating stirring, equipped with a liquid level sensor and overflow pipe to keep the water level in the bath normal.

8. Equipped with a flame detector with automatic fire extinguishing function to ensure the safety of the instrument.

 

Main Specifications:

1. The temperature control range of the cold bath: (0~60)℃;

2. Temperature control accuracy of cold bath: ±0.5℃;

3. The temperature control range of the receiving room: (0~60)℃;

4. Temperature control accuracy of receiving room: ±1℃;

5. Distillation heater: 1000W, 24V;

6. Detection range of distillate volume: (0~100)mL, resolution 0.01mL;

7. Distillate volume measurement accuracy: ≤0.1mL;

8. Working power supply: AC (220±10%) V, 50Hz;

9. Power consumption of the whole machine: 2500W;

10. Use environment: ambient temperature (10~35)℃; relative humidity≤80%;

11. Dimensions: 500㎜×530㎜×660㎜ (length×width×height);

12. Host weight: 85kg.

Diesel Fuel Distillation Range Test Machine

Model: KR-ZL600

The diesel distillation machine is designed and manufactured in accordance with the requirements specified in ASTM D86. It is suitable for test the distillation range for natural gasoline (stable light hydrocarbons), motor gasoline, aviation gasoline, jet fuel, special boiling solvents, naphtha, petroleum spirits, kerosene, diesel, gas oil, distillate fuels and similar petroleum products.

fule distillation machine

Main Parameters:

1. Working power: AC220V ± 10%, 50Hz.

2. Electric furnace heating power: 1000W.

3. Measuring cylinder volume: 100 ml, indexing 1 ml.

4. Distillation flask: 125mL.

5. Electric furnace movable plate: Manufactured by silicon carbide plate, the hole diameter is φ38mm and φ50mm respectively.

6. Temperature controller: 1 Temperature control range: 0~90°C arbitrary setting.

2. Temperature control accuracy: ±0.5 °C.

3. Temperature display mode: LED number.

7. Bath heating power: 1800W

8. Ambient temperature: ≤ +30 °C.

9. Relative humidity: ≤ 85%.

10. Power consumption of the whole machine: no more than 3000W.

 

Online Inquire

ASTM D381 Existent Gum Content Tester

Model: KR-EG19

The KR-EG19 existent gum content in fuel tester is an instrument specially used to determine the actual gum content in aviation gasoline and motor gasoline. It is suitable for the actual gel test of aviation gasoline and motor gasoline according to the method specified in GB/T 8019-2008 “Determination of Fuel Gel Evaporation Method” and ASTM D381 standard, equipped with a dedicated oil-free silent air pressure machine.

existent gum tester

Main technical parameters

1. Power supply: AC (220±10%) V, 50Hz, 3500W.

2. Evaporation bath type and size: Aluminum bath block φ260mm×130mm (diameter×height).

3. Number of test holes: 3.

4. Test hole size: φ51mm×70mm (inner diameter×depth).

5. Working temperature: (160~165)℃.

6. Temperature control method: Automatic temperature control.

7. Temperature display: digital display.

8. Flow rate display: Displayed by floating ball air flow meter.

9. Working pressure of air pressure reducing valve: 0.07MPa.

10. Air flow rate at the outlet of the jet nozzle: (1000±150) mL/sec per hole.

11. Dimensions: 590㎜×480㎜×340mm (length×width×height, excluding thermometer frame).

 

Online Inquire

ASTM D2700 D2699 Octane Testing Equipment

Model: KR-A+

KR-A+ octane tester

The new generation gasoline octane number tester adopts a new appearance design, with “One-Key” used to perform the test automatically and with the maximum knock liquid level searched automatically and accurately without manual operation. The instrument host uses a standard CFR single-cylinder four-stroke engine with a continuous variable compression ratio, to perform the test accurately and eectively by the combination of the industrial control computer, Windows operating system, high-precision measurement and control elements and enrich peripheraldevices, having the auto display, saving and printing test report functions. The product is designed, manufactured and tested according to the
following standards:
ASTM D2700 (Motor Method) GB/T 503-2016 “Determination of Gasoline Octane Number (Motor Method)”
ASTM D2699-08 (Research Method) GB/T 5487-2015 “Determination of Gasoline Octane Number (Research Method)”

 

Instrument Features of Octane Tester

◆ Comply with CFR structure engine
– CFR standard cast iron integral cooling jacket; inblock casted cylinder body and cylinder cover.
– CFR standard crankcase; ve gears with dual balance modules.
– Right-mounted engine, and front turning system
◆ Perfect safety and protection function
– Engine features with soft startup, small start noise and auto run-away protection.
– With the level protection function for the circulating cooling water inside and outside the cooling water tower.
– The indicator used to display the instrument working status.
– The instrument is equipped with a wireless Wi and has a remote monitoring from the movable device, a remote test end alert and a remote data query.
– The engine running pressure negative pressure sensor for real-time display.
– Engine power indicator with digital screen display.
– Auto recording of the cumulative time of startup and test.
◆ Auto “One-Key” operation
– With the auto switching-over of oil cup; with the “One-Key” used to preform
test automatically
– Automatically and accurately nd out the maximum knock liquid level,
without manual search.
– With one machine for dual purposes; with the “One-Key” used to switch over
the Motor Method, Research Method and Test Method.
– With automatic compensation atmosphere pressure module, to ensure the
accuracy of test data.
◆ Accurate control system
– With the accurate compression ratio method test, the built-in work curve for
convenient and accurate test results.
– With the integrated control module, to monitor all working conditions of the
instrument in real time, with abnormity alarm function.
– With high-precision fuel negative pressure pipe (Vertical), fuel quantitative
pipe (Lateral) and air-fuel atomization pipe, to guarantee accurate control of
the oil intake amount of carburetor for stability of test data.
– The fuel negative pressure pipe and fourth oil cup carburetor has the refriger
ation function, to guarantee the light component oil test.
– With high-power dual-cycle air constant-temperature dryer, to eectively
support the air intake of the large-bore engine.
– The machine is integrated with a control intake ice tower and external
circulating cooling water, to feedback the working status in real time.
– A laser displacement sensor is provided, without delay for adjustment, having
the limit safety protection function.
– With two-grade oil ltration and cooling function, the instrument can work
normally for a long time; with the oil emulsication detection function and
with an alarm issued to alert the user to replace oil automatically.
Technical Parameters of octane rating unit
– Octane number test range: 40~120
– CFR standard cast iron integral cooling jacket; inblock casted
cylinder body and cylinder cover
– Cast iron cylinder bore: 82.55mm (3.250in)
– Cast iron piston stroke: 114.3mm (4.50in)
– Cylinder capacity: 0.6L (37.33in3)
– CFR standard crankcase; ve gears with dual balance modules;
right-mounted engine; front turning system
– Main mechanical components such as integral cylinder, holder,
piston and carburetor components can be interchanged with those
of imported instrument.
– Compression ratio adjustment range: 4:1~8:1
– Engine speed: Motor Method: (900±9) r/min
Research Method: (600±6) r/min
– Valve clearance: Intake valve: 0.20mm;
exhaust valve: 0.20±0.025mm
– Spark plug clearance: 0.51±0.13mm
– Lubricant pressure: 172~207Kpa
– Lubricant temperature: 57±8℃
– Cylinder jacket coolant temperature: 100±1.5℃
– Mixed gas temperature (Motor Method): 149±1℃
– Intake temperature (Motor Method): 38±2.8℃
– Intake temperature (Research Method): 52±1℃ (at the standard
atmosphere pressure); corrected according to the atmosphere
pressure within ±1℃
– Ignition advanced angle (Real-time display):
Motor Method ε5.0 (26±1.5℃); adjusted by the computer automatically
Research Method (13º); xed
– High-power dual-cycle refrigeration ice tower; with 2-4℃ controlled
– High-power cooling water circulating machine; with the water tank
capacity of ≥60L; water pressure: 0.2~0.4MPa; working water
temperature: 15~25℃
– Power supply: AC380V±10%, 50Hz; AC220V±10%, 50Hz
– Machine power: 12KW; accessories power: 7KW
– Instrument size: 1780W x 900D x 1400H (mm)
– Machine weight: 1200kg
Online Inquire