Digital Closed Cup Flash Point Test Equipment

Model: KR-S8

The manufacture of this instrument conforms to the method specified in GB/T261-2008 “Petroleum Products Flash Point Method (Closed Cup Method)”. After the petroleum product sample is heated in a closed oil cup, the oil vapor and surrounding air are generated. When the mixed gas is in contact with the flame to produce a flash fire, the lowest temperature of the test oil is the flash point of the petroleum product sample.

closed cup flash point meter

Features:

1. Digital display, heating temperature manually adjustable.
2. Furnace with heating rod heating, long life, good stability.
3. With constant speed motor shaft stirring, two kinds of stirring speed selection.
4. Valve to adjust the flow, safe and reliable, high precision, good sealin.

Technical Parameters:

Working power supply AC220V±10%, 50Hz.
Heating device (1) The furnace body is silicon carbide material and the power is 600W electric heating wire.

(2) Heating power can be adjusted from 0 to 600W.

Sample heating rate 1 ~ 12 ° C / min.
Electric stirring device (1) Stirring motor: Constant speed motor.

(2) Transmission mode: flexible shaft coupling.

(3) Stirring blade size: 8 × 40 (mm).

Standard oil cup (1) Inner diameter: 50.8 mm.

(2) Depth: 56 mm.

(3) Test oil capacity Marking depth: 34.2 mm.

(4) Test oil capacity: about 70 ml.

Fire-fighting device Fire source: gas

fire igniter aperture: 0.8 mm.

Temperature meter Internal standard mercury thermometer, in line with the provisions of GB514.

Scale: -30 ~ 170 ° C, index: 1 ° C.

Scale: 100 ~ 300 ° C, index: 1 ° C.

Ambient temperature ≤35℃
Relative humidity ≤85%
Machine power consumption No more than 650W.
Online Inquire

Manual Open Cup Flash Point Instrument

Model: KR-K8

flash point test machine

This manual type open cup flash point test equipment complies with the requirements stipulated in GB/T3536-2008 “Cleveland Open Cup Method for the Determination of Flash Point of Petroleum Products”, and is applicable to the determination of petroleum products and asphalt with an open cup flash point higher than 79 °C except for fuel oil. It mainly consists of an ignition device, a sweeping device, a heating device and a temperature control system.

 

Main Specifications:

1. Working power: AC 220V ± 10%, 50Hz.

2. Heating device: Quartz tube electric furnace heating, no open flame, explosion-proof, power continuously adjustable.

3. Temperature meter: -6-400 ° C, index 2 ° C, technical conditions in line with the technical requirements of petroleum products for testing liquid thermometer GB/T514

4. Ignition device: ignition source is gas (or other civil flammable gas), orifice diameter: 0.6-0.8mm

5. Ambient temperature: -10 °C ~ 50 °C.

6. Relative humidity: ≤ 85%.

7. The machine power consumption: no more than 650W.

 

Online Inquire

Automatic Cleveland Open Cup Flash Point Analyzer

Model: KR-K800

Cleveland open cup flash point tester

This automatic open cup flash ignition point tester is manufactured according to GB267 “Petroleum product flash point and ignition point measurement method (open cup method)”, GB3536 “Petroleum product flash point and ignition point measurement method (Cleveland open cup method)” standard method, It is an ideal instrument for performing flash point testing in petroleum, chemical, electric power, environmental protection, railway, scientific research and other fields.

 

Main Features:

1. Adopt high-speed signal processor control, adaptive PID control algorithm, and automatically adjust the heating curve according to standard requirements.

2. Built-in atmospheric pressure automatic detection chip, automatic measurement of atmospheric pressure, automatic correction of flash point value.

3. Data storage function, can store 300 results, and check the history at any time.

4. Differential detection, automatically correct system deviation and stop detecting and alarming when the temperature exceeds the value.

5. The instrument automatically completes lifting, stirring, ignition, detection, alarm, cooling, and printing.

6. Safe airless source, platinum alloy electric heating wire ignition mode, safe, stable, reliable, high test accuracy.

 

Technical parameters of flash point analyzer:

Display 10 inch 65K(resolution 800*600) Chinese and English touch screen
Measurement method Thermocouple differential detection
Measuring range room temperature to 400 ° C
Repeatability ±4℃
Printer High speed thermal printer, 56 mm paper width
Ignition method automatic electronic ignition
Temperature detection imported precision platinum resistance
Self-test function printer, igniter, solenoid valve, detection arm lift, ignition rod sweep, etc.
Dimensions 450*280*290mm
Power source AC220V±10%
Weight about 15 kg

 

Online Inquire

ASTM D93 Pensky-martens Closed Cup Flash Point Apparatus

Model: KR-S800

closed cup flash point tester

This automatic closed cup point flash point apparatus is manufactured according to the national standard GB/T261-2008 “Pensky-Martens closed cup method for flash point determination” and ASTM D93 standard, applied in petroleum, chemical, electric power, environmental protection, railway, scientific research departments, etc., is ideal instrument for closed flash point testing.

 

Main Features:

1. Adopt high-speed signal processor control, adaptive PID control algorithm, and automatically adjust the heating curve according to standard requirements.

2. Built-in atmospheric pressure automatic detection chip, automatic measurement of atmospheric pressure, automatic correction of flash point value.

3. Optional Chinese and English operation interface, instrument program can be upgraded when national standards are revised.

4. Differential detection, automatically correct system deviation and stop detecting and alarming when the temperature exceeds the value.

5. The instrument automatically completes lifting, stirring, ignition, detection, alarm, cooling, and printing.

6. Safe airless source, platinum alloy electric heating wire ignition mode, safe, stable, reliable, high test accuracy.

 

Main Technical Parameters:

Display 10 inch 65K(resolution 800*600) Chinese and English touch screen
Measurement method Thermocouple differential detection
Measuring range Room temperature to 400 ° C (to determine the sub-zero temperature flash point, you need to freeze the sample first.)
Resolution 0.1 °C
Repeatability National standard: tolerance value ±1 °C when flash point value<104 °C, tolerance ±2 °C when flash point value ≥104 °C.

International standard: tolerance ±1 °C when the flash point value is ≤110 °C, tolerance ±2 °C when the flash point value is >110 °C.

Printer High speed thermal printer, 56 mm paper width
Ignition method Airless source electronic ignition
Temperature detection Imported platinum resistance (Pt100Ω)
Self-test function automatic diagnosis of instrument failure
Cooling method forced air cooling
Dimensions 450*280*290mm
Power source AC220V±10%
Weight about 15 kg

 

Online Inquire

 

Oil Tag Closed Cup Flash Point Tester

Model: KR-D56

The tag flash point analyzer conforms to the requirements of NY/T1860.11-2016, GB/T 21929-2008, and ASTM D56 standards.

The flash point tester (tag method) adopts mixed signal ISP FLASH microcontroller as the core, and the whole measurement process is carried out automatically except for sample filling. The 65K true color touch screen makes the operation more convenient, clear and intuitive. It is widely used in chemical, pesticide, railway, aviation, electric power, petroleum industries and scientific research departments.

flash point tester tag method

This instrument is mainly used to determine the flash point of liquids with a viscosity less than 5.5mm2/s at 40°C, or a viscosity less than 9.5mm2/s at 25°C, and a flash point lower than 93°C.

Main technical parameters of KR-D56

Applicable standards: NY/T1860.11-2016, GB/T 21929-2008, ASTM D56
1. Test range: 0℃~100℃ (optional for water bath)
2. Display accuracy: 0.1℃
3. Heating rate: 1℃/min below 60℃; 3℃/time above 60℃
4. Test time: 0.5℃/time below 60℃; 1℃/time above 60℃
5. Sample quantity: 50ml
6. Test interval: 0.1℃~5℃ can be set
7. Ignition device: gas ignition
8. Result processing: automatic correction and printout of results
9. Sample cup material: copper cup
10. Refrigeration method: imported compressor cascade cycle refrigeration
11. Voltage/power: AC220V±10% 50Hz; host 500W/refrigeration bath 1500W
12. Dimensions: 40*30*28 (cm)

Instrument Characteristics

1. This tag closed cup flash point tester is controlled by a touch screen microcomputer, which integrates temperature control, ignition, flash point capture, storage, and printing into one and completes it automatically.
2. 65K true color 5.7 inch LCD color screen, with touch keyboard, automatic brightness and contrast adjustment.
3. Built-in standard programs and non-standard programs for users to switch.
4. The test result is automatically corrected to the standard atmospheric pressure; the flash point is automatically detected, and it can also be captured manually; automatically open lid ignition, can also be manually ignited.

5. The program automatically prompts the amount of sample added according to the test temperature, and adjusts the timing range, which is safe and reliable;
6. The experiment results are automatically printed, and the flash point alarm prompt is found.
7. Equipped with multifunctional circulating cooling water bath, automatic/manual control of cooling medium circulation.
8. This oil flash point test machine can be equipped with an optional embedded cup (0.05mm) and upper mold, which is convenient for removing samples, convenient for loading and unloading, beautiful appearance, reasonable structure, and simple operation.

Online Inquire

ASTM D92 Cleveland Open Cup Fire Point Tester

Model:KR106B

This automatic open cup flash and fire point tester, according to the People’s Republic of China standard GB/T 3536 “Petroleum product flash point and ignition point method (Cleveland open cup method)” and GB/T267-1988 petroleum products flash point and ignition point determination method Designed and manufactured according to the requirements specified in the (open cup method) and ASTM D92 standard.

open cup flash point tester

Instrument characteristics

1. This flash point measuring instrument adopts color LCD large screen display, English man-machine dialogue interface, no identification keyboard, and has parameters such as pre-valued temperature, sample label, atmospheric pressure, test date, etc., with prompt menu and guide input function.

2. The analog tracking shows the function curve of temperature rise and test time. It has the micoperation software prompt modification function, and is equipped with parameter prompt function such as test date and test time.

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.

4. Differential detection, system deviation is automatically corrected.

5. The sweeping, detecting and printing data is automatically completed, and the test arm is automatically raised and dropped.

6. Electronic ignition, forced air cooling.

7. Can do not need air source automatic ignition, improve the safety of the test.

 

Technical Parameters:

1. Working power: AC220V ± 10%, 50Hz

2. Temperature measurement: range: room temperature ~ 400 ° C.

Repeatability: flash point ≤150°C error ±2°C

flash point ≥150°C error ±3°C

Resolution: 0.1 ° C; accuracy: 0.5%.

3. Heating rate: in line with GB/T3536 standard.

4. Ignition mode: electronic ignition, gas flame 3mm~4mm.

5. Ambient temperature: (10~40) °C.

6. Relative humidity: ≤80%.

 

Online Inquire

ISO 3679 Balance Method Closed Cup Flash Point Tester

KR05D model balance method low temperature closed flash point meter is designed and manufactured according to the requirements of the People’s Republic of China standard GB / T 5208 “Determination of the flash point of the rapid balance closed cup method”. This instrument also meets the requirements of ISO 1523 and ISO 3679.

flash point tester

The instrument is based on advanced electronic temperature control instrument, equipped with appropriate interface circuit to realize temperature control automation, automatic heating power switching, automatic temperature control and other functions. The instrument is simple in operation, reasonable in structure, accurate in detection, stable in performance and intuitive in display. It is an ideal substitute for fast flash point testing of petroleum, chemical, paint, paint, railway, aviation, electric power, commodity inspection, military and scientific research units.

This instrument is especially suitable for the test of all kinds of color paints, paints, adhesives, solvents, petroleum and related products in the closed cup flash point in the range of -30 ° C ~ + 100 ° C.

Technical Parameters:

1. Working power: AC220V ± 10%, 50Hz;
2. Flash point detection range: (-20 ~ + 80) ° C;
3. Measurement precision: the absolute difference between the two experimental results is less than 2 ° C (same operator);
The absolute difference between the two experimental results is less than 3 ° C (different operators);
4. Temperature control accuracy: ± 0.5 ° C;
5. Ignition device: electronic ignition gun ignition;
6. Cooling method: semiconductor refrigeration
7. The power supply voltage: AC220V ± 10%, 50Hz;
8. The whole machine power: no more than 300W;
9. Ambient temperature: 5 ° C ~ 30 ° C;
10. Relative humidity: (30~80) %.

 

Online Inquire

Open Cup and Closed Cup Flash Point Tester in One Machine

Model: KR-SK800

flash point tester

As you can see from above picture, this machine can perform both open cup and closed cup flash point testing which can save the cost and space for laboraotory.

KR-SK800 automatic closed cup and open cup flash ignition point tester is manufactured according to GB/T261-2008 “Binsky-Martin closed cup method for flash point determination”, ASTM D93 standard, GB267 “Petroleum product flash point and ignition point measurement method (open cup method) and GB3536 “Petroleum product flash point and ignition point measurement method (Cleveland open cup method)” standard method. It is an ideal instrument for performing flash point testing (closed cup and open cup) in petroleum, chemical, electric power, environmental protection, railway, scientific research and other fields.

Main Features:

1. Adopt high-speed signal processor control, adaptive PID control algorithm, and automatically adjust the heating curve according to standard requirements.

2. Built-in atmospheric pressure automatic detection chip, automatic measurement of atmospheric pressure, automatic correction of flash point value.

3. Data storage function, can store 300 results, and check the history at any time.

4. Differential detection, automatically correct system deviation and stop detecting and alarming when the temperature exceeds the value.

5. The instrument automatically completes lifting, stirring, ignition, detection, alarm, cooling, and printing.

6. Safe airless source, platinum alloy electric heating wire ignition mode, safe, stable, reliable, high test accuracy.

7. Optional Chinese and English operation interface, instrument program can be upgraded when national standards are revised

Main Technical Parameters:

Display 10 inch 65K(resolution 800*600) Chinese and English touch screen
Measurement method Thermocouple differential detection
Measuring range Open cup: room temperature to 400 ° C, closed cup: room temperature to 350 ° C
Repeatability Closed cup: National standard: tolerance value ±1 °C when flash point value<104 °C, tolerance ±2 °C when flash point value ≥104 °C.

International standard: tolerance ±1 °C when the flash point value is ≤110 °C, tolerance ±2 °C when the flash point value is >110 °C.

Open Cup: ±2℃

 

Resolution 0.1 °C
Printer High speed thermal printer, 56 mm paper width
Ignition method Airless source electronic ignition
Temperature detection imported precision platinum resistance
Cooling method forced air cooling
Self-test function automatic diagnosis of instrument failure
Power consumption <550W
Operating environment Temperature 10 ° C -45 ° C, humidity 30-80%
Dimensions 450*280*290mm
Power source AC220V±10%
Weight about 15 kg

 

Online Inquire