Inductively coupled plasma emission spectrometer, as a professional laboratory analysis instrument, has many characteristics such as testing multiple elements, being able to detect up to 70 elements, fast testing speed, and low detection limit. Not only has the efficiency of solid-state RF power supply and instrument status monitoring functions been optimized and upgraded from the perspective of instrument configuration, but also functions such as audit tracking, flame video display, and direct display of sample results when tracing samples have been integrated into the software. The stability of the instrument and the convenience of software operation are closer to customer use, providing customers with a better experience. The whole machine has a high degree of automation and intelligence, and the software operation is simple and easy to learn.
Real time observation window for flames
The instrument is equipped with a highly sensitive flame sensing system and a visual video monitoring camera, which can observe the flame status of the combustion chamber in real-time and automatically turn off the RF power supply when the engine is turned off, protecting important components of the instrument.
Safe and reliable airflow protection function
The instrument is equipped with an argon gas monitoring and protection device. When the argon gas is below the safety limit for use, the instrument will automatically turn off the working power and immediately issue an alarm reminder to avoid damage to the equipment due to the depletion of argon gas.
Peristaltic pump injection device
The instrument is equipped with a high-precision peristaltic pump with five channels and sixteen rollers, which can ensure the accuracy of sample injection and prevent liquid accumulation at the same time. The rotational speed of the peristaltic pump is continuously adjustable, meeting various testing requirements of customers.High precision airflow control and protection system
The plasma gas, auxiliary gas, and carrier gas in the instrument’s operation are all controlled by an integrated high-precision mass flow controller (MFC), with an accuracy of 0.01L/min. It has continuously adjustable flow rate and high accuracy in outputting airflow, ensuring the accuracy of test data.
High precision constant temperature system
The overall optical path of the instrument is protected by a precision constant temperature system. The temperature control can be set in real time according to the actual environmental temperature of the customer’s laboratory, without the need for continuous adjustment for a long time. The temperature control accuracy is <# 0.1 °C. The precision constant temperature system ensures the stability of the optical path, and the test data is more stable.
Automatic adjustment of observation position
The plasma flame can be adjusted in three dimensions (controlled by a computer), including front and back, up and down, and left and right. It integrates an integrated quartz torch tube, which can achieve one second positioning of the torch tube and complete replacement in ten seconds, ensuring the performance of the instrument after replacing the torch tube. Find optimized observation positions through feedback signal values to obtain strong sensitivity and accurate testing results.
Optional audit tracking function
The software is equipped with audit tracking function, which can set multi user and multi permission settings. Users can open and allocate account permissions according to their needs, and have complete operation log records, as well as permissions and notes for modifying and deleting data. It can also save measured data to the server for backup.
This feature has a prominent role in many fields, such as drug safety, where multiple departments can share data, set different levels of permissions for data access, and facilitate daily data retrieval and use;Data is stored for a long time and cannot be changed, greatly ensuring the accuracy of the data and facilitating data traceability.
Convenient software operation experience
High degree of instrument automation
Except for the power switch, all operations are completed by software. Intelligent
software that can provide real-time feedback and information prompts for various operations. Fully automatic one click ignition is possible, and all parameter settings are automatically changed. With advanced automatic matching technology, the ignition success rate is high and the operation is simple.
Ultra simple software operation interface
A simple and clear software operation interface, all icons are clear at a glance, just click in the order of the icons to complete all tests. Proficient mastery without the need for professional technical guidance.
Software optimization algorithm
By optimizing software algorithms, real- time matrix deduction can be achieved, and two-dimensional coordinates can be zoomed in and out in real-time for spectra with interference. This facilitates spectral processing, automatically calculates results with one click, and eliminates the cumbersome data processing for customers.
Ultra high resolution optical system
The instrument can be equipped with imported gratings with ultra-high resolution 4320 lines, combined with unique optical path adjustment technology, which reduces the resolution of ordinary instruments from about 0.008nm to within 0.005m. The ultra-high resolution ensures that there is no mutual interference between test elements.